Refine your search:     
Report No.
 - 
Search Results: Records 1-4 displayed on this page of 4
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Comprehensive exposure assessments from the viewpoint of health in a unique high natural background radiation area, Mamuju, Indonesia

Nugraha, E. D.*; Hosoda, Masahiro*; Kusdiana*; Untara*; Mellawati, J.*; Nurokhim*; Tamakuma, Yuki*; Ikram, A.*; Syaifudin, M.*; Yamada, Ryohei; et al.

Scientific Reports (Internet), 11(1), p.14578_1 - 14578_16, 2021/07

 Times Cited Count:19 Percentile:83.39(Multidisciplinary Sciences)

Mamuju is one of the regions in Indonesia which retains natural conditions but has relatively high exposure to natural radiation. The goals of the present study were to characterize exposure of the entire Mamuju region as a high natural background radiation area (HNBRA) and to assess the existing exposure as a means for radiation protection of the public and the environment. A cross-sectional study method was used with cluster sampling areas by measuring all parameters that contribute to external and internal radiation exposures. It was determined that Mamuju was a unique HNBRA with the annual effective dose between 17 and 115 mSv, with an average of 32 mSv. The lifetime cumulative dose calculation suggested that Mamuju residents could receive as much as 2.2 Sv on average which is much higher than the average dose of atomic bomb survivors for which risks of cancer and non-cancer diseases are demonstrated. The study results are new scientific data allowing better understanding of health effects related to chronic low-dose-rate radiation exposure and they can be used as the main input in a future epidemiology study.

Journal Articles

Low-dose radiation risk and individual variation in radiation sensitivity in Fukushima

Fukunaga, Hisanori*; Yokoya, Akinari

Journal of Radiation Research, 57(1), p.98 - 100, 2016/01

 Times Cited Count:8 Percentile:85.58(Biology)

Journal Articles

Usage of a capillary plate as a pre-gas-amplification device for a neutron microstrip gas chamber

Nakamura, Tatsuya; Masaoka, Sei; Yamagishi, Hideshi; Sakasai, Kaoru; Soyama, Kazuhiko; Aizawa, Kazuya

IEEE Transactions on Nuclear Science, 51(4), p.1519 - 1523, 2004/08

 Times Cited Count:2 Percentile:18.4(Engineering, Electrical & Electronic)

A capillary plate (CP) comprising an assembly of fine glass tubes was applied as a pre-gas-amplification device for a microstrip gas chamber (MSGC) operating under high-gas pressure of helium-3 for use in neutron detection. The collection efficiency of the electrons between the CP and MSGC was maximally 17% using neutrons. The effective gas gain of the detector system was $$sim$$600 at a gas pressure of 3 atm with a 10% mixture of ethane with helium-3, confirming the feasibility of the CP as a pre-gas-amplification device. Moreover, we demonstrated that the coincidence measurement of the signals between the CP and the anodes of MSGC decreased the background levels of electronics noise, electronic discharges, and $$gamma$$-rays, indicating that a detector system with a low background can be constructed using the CP.

Oral presentation

Study of the neutron absorbers materials coated on the back side of analyzer silicon crystal wafer

Shibata, Kaoru

no journal, , 

The silicon crystal analyzer is an important spectroscopic device for high energy resolution neutron inelastic backscattering spectrometer. Specification of this spectroscopic device is thought to determine energy resolution and background. In order to achieve a low background spectrum without degradation of the energy resolution, it was developed new crystal analyzer which were constracted by Si wafers coated by thin film of neutron absorbers on the back side of Si wafer, and used it for the new backscattering spectrometer DNA in MLF at J-PARC which were able to achieve the desired performance.

4 (Records 1-4 displayed on this page)
  • 1